10, 15, 20, and 30 um ID C18 Columns

We provide 10−30 μm ID nanoLC columns for ultrasensitive mass spectrometry proteomic analysis of a single mammalian cell (e.g., ~15 μm size, 0.1−0.2 ng protein content per cell), small populations of cells (e.g., a few to 100 mammalian cells), and tiny specimen of tissue (e.g., <0.1 mm).  Combined with advanced methods of proteome sample processing and mass spectrometry analysis, these ultrasensitive nanoLC columns provide a capability to assign 1,500−5,000 proteins from 1−100 mammalian cells.  These very narrow columns can also be adopted for other applications where ultrasensitive nanoLC–mass spectrometry analysis is needed.

We also provide micro-solid phase extraction columns for robust, rapid, and total recovery loading of small sizes of samples in ultrasensitive nanoLC–mass spectrometry analysis. 

Product #DimensionsPacking ParticlesFlow Rate (nL/min)Operation Pressure (psi)Column FeaturePrice($)
USB01002001718I10 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Integrated1,100
USB01003001718I10 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Integrated1,300
USB01502001718I15 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Integrated1,000
USB01503001718I15 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Integrated1,150
USB02002001718I20 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Integrated800
USB02003001718I20 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Integrated900
USB02004001718I20 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<8000 Integrated1,100
USB03002001718I30 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Integrated650
USB03003001718I30 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Integrated750
USB03004001718I30 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Integrated850
USB03005001718I30 um ID x 50 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Integrated1,050
USB03006001718I30 um ID x 60 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Integrated1,350
USB03004003018I30 um ID x 40 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Integrated550
USB03005003018I30 um ID x 50 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Integrated650
USB03006003018I30 um ID x 60 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Integrated750
USB03007003018I30 um ID x 70 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated850
USB03008003018I30 um ID x 80 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated950
USB03009003018I30 um ID x 90 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated1,150
USB03010003018I30 um ID x 100 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated1,450
USB01002001718IWF10 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Integrated1,300
USB01003001718IWF10 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Integrated1,500
USB01502001718IWF15 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Integrated1,200
USB01503001718IWF15 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Integrated1,350
USB02002001718IWF20 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Integrated1,000
USB02003001718IWF20 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Integrated1,100
USB02004001718IWF20 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<8000 Integrated1,300
USB03002001718IWF30 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Integrated750
USB03003001718IWF30 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Integrated850
USB03004001718IWF30 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Integrated950
USB03005001718IWF30 um ID x 50 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Integrated1,150
USB03006001718IWF30 um ID x 60 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Integrated1,450
USB03004003018IWF30 um ID x 40 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Integrated650
USB03005003018IWF30 um ID x 50 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Integrated750
USB03006003018IWF30 um ID x 60 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Integrated850
USB03007003018IWF30 um ID x 70 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated950
USB03008003018IWF30 um ID x 80 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated1,050
USB03009003018IWF30 um ID x 90 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated1,250
USB03010003018IWF30 um ID x 100 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Integrated1,550
USB01002001718S10 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Separated900
USB01003001718S10 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Separated1,100
USB01502001718S15 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Separated800
USB01503001718S15 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Separated1,000
USB02002001718S20 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Separated650
USB02003001718S20 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Separated750
USB02004001718S20 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Separated900
USB03002001718S30 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Separated500
USB03003001718S30 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Separated600
USB03004001718S30 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Separated700
USB03005001718S30 um ID x 50 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Separated900
USB03006001718S30 um ID x 60 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Separated1,200
USB03004003018S30 um ID x 40 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Separated500
USB03005003018S30 um ID x 50 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Separated600
USB03006003018S30 um ID x 60 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Separated700
USB03007003018S30 um ID x 70 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated800
USB03008003018S30 um ID x 80 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated900
USB03009003018S30 um ID x 90 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated1,100
USB03010003018S30 um ID x 100 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated1,400
USB01002001718SWF10 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Separated1,100
USB01003001718SWF10 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)3 ± 2<5000 Separated1,300
USB01502001718SWF15 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Separated1,000
USB01503001718SWF15 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)8 ± 3<5000 Separated1,200
USB02002001718SWF20 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Separated850
USB02003001718SWF20 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<5000 Separated950
USB02004001718SWF20 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)15 ± 5<8000 Separated1,100
USB03002001718SWF30 um ID x 20 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Separated700
USB03003001718SWF30 um ID x 30 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<5000 Separated800
USB03004001718SWF30 um ID x 40 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Separated900
USB03005001718SWF30 um ID x 50 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Separated1,100
USB03006001718SWF30 um ID x 60 cm L x 365 um OD1.7 um C18 (100A)30 ± 10<8000 Separated1,400
USB03004003018SWF30 um ID x 40 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Separated700
USB03005003018SWF30 um ID x 50 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Separated800
USB03006003018SWF30 um ID x 60 cm L x 365 um OD3 um C18 (300A)30 ± 10<5000 Separated900
USB03007003018SWF30 um ID x 70 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated1,000
USB03008003018SWF30 um ID x 80 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated1,100
USB03009003018SWF30 um ID x 90 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated1,300
USB03010003018SWF30 um ID x 100 cm L x 365 um OD3 um C18 (300A)30 ± 10<8000 Separated1,600

Note 1: Not-fitted columns (i.e., bare columns without fittings) are for users to flexibly utilize the columns according to users’ specific instrument setups, while columns with fittings (WF, 1/16” VICI-type) are for conventional nanoLC instrument configurations. 2: MicroSPE columns are typically needed for quick sample loading as these ultrasensitive columns are operated at very low flows. 3: The nanoLC operation pressure listed is for the column operated at the middle value of the flow range (at room temperature). 4: Other dimensions of USB columns can be specially ordered.